Framed Acoustical Panel with Fiberglass Core
PS80AL Acoustical Panel

The PS80AL’s aluminum frame makes it an ideal choice of acoustical panels for installations where added structural stability is important. The fabric or perforated wallcovering you choose will be beautifully wrapped around the front and sides of the panel. The PS80AL is available in 1-5/16″ or 2-5/16″ thicknesses, and a maximum width of 5 feet when covered with fabric. If your height requirements are greater than ten feet, custom construction can be arranged.

Options available in core material and coverings allow rooms to be designed for the maximum in acoustical performance.

INSTALLATION

PS80AL panels may be affixed with factory installed Z-Clips, Hook and Loop fasteners, Adhesive, or Magnets (leveling angles provided).

Specialty Interior Finish Products - Acoustical Panels

PS80AL Noise Reduction Coefficient Rating

Panel
Type
DensityThkCover125
HZ
250
HZ
500
HZ
1000

HZ
2000

HZ
4000

HZ
NRC
PS80AL4 lb.1"FR7010.140.290.741.011.101.300.80
PS80AL7 lb.1"Vinyl0.220.360.821.110.980.860.80
PS80AL6 lb.1"Polyolefin0.130.451.140.810.650.710.75
PS80AL7 lb.2"FR7010.510.960.981.010.950.981.00
PS80AL7 lb.2"Vinyl0.210.851.151.070.910.901.00

PS80AL Specifier - Panel & Use Reference

PanelPS80AL
FunctionNoise Reduction,
Fiberglass Lb Core DensityInternal perimeter Aluminum frame, 4-7 lb. density
Nominal Thickness1-5/16” & 2-5/16”
Edge DetailSquare, Bevel, Radius
Install
Methods
Adhesive Z-Clip Hook & Loop, Leveling Angles Utilized on All.
CoveringFabric, Polyolefin,
NRC Est.1-5/16” = 0.80
2-5/16” = 1.00

• Acoustical Panel Thickness & Covering changes NRC values, following is general guide.
• Our mill standard covering is Guilford of Maine FR701-2100 series.
• Covering MUST allow sound waves to travel thru the covering for any absorbing.
• NRC values shown are based on selection made for thickness, covering, and all other options.  Questions Inquire.
• Review Noise Coefficient Rating for Panel type / Thickness / Density / Covering found at bottom of page for each panel Type on web page Menu choices.

acoustical panel

Framed Acoustical Panel with Fiberglass Core
PS90ALD Acoustical Panel

When you want aesthetics as well as greater impact resistance and a tackable surface, choose the PS90ALD. It offers the identical properties of the PS80AL, but adds a molded 1/8″ fiberglass hardboard that helps it stand up to the punishment of heavy traffic areas. It’s available in 1-7/16″ or 2-7/16″ thicknesses and dimensions greater than 48″ x 120″ when required.

INSTALLATION

PS90ALD panels may be affixed with factory installed Z-Clips, Hook and Loop fasteners, Adhesive, or Magnets (leveling angles provided).

PS90ALD Samples

PS90ALD 1-7/16"

Front View

1-7/16" Acoustical Panel with Bevel Edges and Corners with Guilford of Maine FR701 Fabric.
PS90ALD 1-7/16"

Profile View

1-7/16" Acoustical Panel with Bevel Edges and Corners with Guilford of Maine FR701 Fabric.
PS90ALD 1-7/16"

Front View - Cut Away

1-7/16" Acoustical Panel with Square Edges and Corners with Guilford of Maine FR701 Fabric.
PS90ALD 1-7/16"

Profile View - Cut Away

1-7/16" Acoustical Panel with Square Edges and Corners with Guilford of Maine FR701 Fabric.
PS90ALD 1-7/16"

Front View - Cut Away

1-7/16" Acoustical Panel with Square Edges and Corners with Guilford of Maine FR701 Fabric.
PS90ALD 1-7/16"

Profile View - Cut Away

1-7/16" Acoustical Panel with Square Edges and Corners with Guilford of Maine FR701 Fabric.

PS90ALD Noise Reduction Coefficient Rating

Panel
Type
DensityThkCover125
HZ
250
HZ
500
HZ
1000

HZ
2000

HZ
4000

HZ
NRC
PS90ALD4 - 14 lb.1"FR7010.160.550.981.030.971.010.90
PS90ALD7 - 18 lb.1"FR7010.310.550.891.071.051.150.90
PS90ALD7 - 18 lb.2"Vinyl0.280.691.071.111.061.081.00

PS90ALD Specifier - Panel & Use Reference

PanelPS90ALD
FunctionNoise Reduction, Tackable, Impact Resistant
Fiberglass Lb Core DensityInternal perimeter
Aluminum frame,
4-7 lb. density, +
1/8”F.G. @ 18 lb.
Density
Nominal Thickness1-7/16” & 2-7/16”
Edge DetailSquare, Bevel, Radius
Install
Methods
Adhesive Z-Clip Hook & Loop, Leveling Angles Utilized on All.
CoveringFabric, Polyolefin,
NRC Est.1-7/16” = 0.90
2-7/16” = 1.00

• Acoustical Panel Thickness & Covering changes NRC values, following is general guide.
• Our mill standard covering is Guilford of Maine FR701-2100 series.
• Covering MUST allow sound waves to travel thru the covering for any absorbing.
• NRC values shown are based on selection made for thickness, covering, and all other options.  Questions Inquire.
• Review Noise Coefficient Rating for Acoustical Panel type / Thickness / Density / Covering found at bottom of page for each panel Type on web page Menu choices.

PRICE: